Features
Advantages
Triple Action Filter
Triple Action Filter with Vitamin C, Silver Ion and Cold Catalyst protects your skin and improves the air quality.
Golden Fin
The golden coating of the new Nobu indoor and outdoor unit ensures maximum protection for your air conditioner, boosting its performance, extending its lifetime and improving the air quality in the room. Thanks to the anti-corrosion composition of the hydrophilic coating on the outdoor unit, the resistance to corrosive elements such as rain increases is improved, while the golden coating on the indoor unit prevents the bacteria from reproducing and spreading in space, creating a healthy and comfortable environment.
Powerful Self-Cleaning
With a touch of a button on the remote control your air conditioner cleans itself! The process only takes up a few minutes. When it is finished, the unit is ready to be used again, clean from bacteria and fungi, providing fresh and clean air.
Automatic Louvers' Movement
Dispense cold/warm air at max range with automatic horizontal movement louvers
Absolute Silent Mode
Enable "Ultra Silence" mode and enjoy the feeling of absolute quite in your place
Heating 8°C
Avoid possible damage from weather events in areas that are not heated during the winter, in the most economical way. Activate the 8°C function and the air conditioner will heat the room as much as needed, keeping the temperature constant at 8°C. Protect the objects in your room and ensure low consumption with maximum energy savings in the winter season.
Sleep Mode
With the Sleep Mode, the airconditioner adjusts the room temperature for perfect sleeping conditions and energy saving.
Turbo Mode
This function gives more impulse to the cooling and heating operation for a time period contribute to the room's direct cooling or heating
24- hour Timer
Set the unit to start and stop automatically in a 24h period.
Auto Restart
If the air conditioner breaks off unexpectedly due to the power cut, it will restart with the previous setting mode automatically when the power resume.
Technical Specifications
- NBKU3VI-09WFI/ NBKU3VO-09
- Cooling Capacity 9.000 (3.100-11.600) Btu / h
- Cooling Capacity 2.64 (0.91-3.40) kWatt
- Heating Capacity 10.000 (2.800-11.500) Btu / h
- Heating Capacity 2.93 (0.82-3.37) kWatt
- Seasonal Efficiency In accordance to ΕΝ14.825
- Cooling
- Pdesign 2.6 kW
- Energy Class A++
- SEER 7.0
- Energy Consumption 130 kWh / year
- Heating Middle Zone
- Pdesign 2.3 kW
- Energy Class A+
- SCOP 4.1
- Energy Consumption 7392 kWh / year
- Heating Warm Zone
- Pdesign 2.3 kW
- Energy Class A+++
- SCOP 5.1
- Energy Consumption 665 kWh / year
- Voltage / Frequency / Phase 220-240/50/1 V / Hz / Ph
- Current Input Cooling 3.48 (0.4-5.4) Α
- Current Input Heating 4.05 (0.5-5.5) Α
- Power Input Cooling 0.8 (0.1-1.24) kW
- Power Input Heating 0.93 (0.12-1.2) kW
- Air Flow Volume 435/333/259 High / Med / Low
- Sound Power Level Indoor Unit 21.5/25/32/37 Quiet / Low / Medium / High / Turbo
- Sound Power Level Outdoor Unit 55 db(A)
- Sound Power Level Indoor Unit 50 db(A)
- Sound Power Level Outdoor Unit 59 db(A)
- Dehumidifying Volume 0.8 L/h
- Dehumidifying Volume 28.8 L/day
- Compressor Type ROTARY
- Liquid Line / Gas Line 1 / 4” - 3 / 8”
- Power Supply Wire Outdoor 3 x 1.5 / 10 Α
- Signal Wires 5 x 1.5 No x mm²
-
Dimensions
Indoor Unit 715x194x285 WxDxH -
Dimensions
Outdoor Unit 720x270x495 WxDxH - Net Weight Indoor / Outdoor 6.7/21.0 kg
- Refrigerant / Quantity R32/470 g
- Operation Temperature Range Outdoor Unit Cooling -15~50 °C
- Operation Temperature Range Outdoor Unit Heating -20~30 °C
- NBKU3VI-12WFI/ NBKU3VO-12
- Cooling Capacity 12.000 (3.800-13.400) Btu / h
- Cooling Capacity 3.52 (1.11 - 3.93) kWatt
- Heating Capacity 13.000 (3.700-14.200) Btu / h
- Heating Capacity 3.81 (1.08 - 4.16) kWatt
- Seasonal Efficiency In accordance to ΕΝ14.825
- Cooling
- Pdesign 3.5 kW
- Energy Class A++
- SEER 6.5
- Energy Consumption 188 kWh / year
- Heating Middle Zone
- Pdesign 2.8 kW
- Energy Class A+
- SCOP 4.1
- Energy Consumption 957 kWh / year
- Heating Warm Zone
- Pdesign 3.0 kW
- Energy Class A+++
- SCOP 5.2
- Energy Consumption 823 kWh / year
- Voltage / Frequency / Phase 220-240/50/1 V / Hz / Ph
- Current Input Cooling 5.8 (0.8-7.3) Α
- Current Input Heating 5.3 (1.4-6.4) Α
- Power Input Cooling 1.32 (0.83-1.6) kW
- Power Input Heating 1.19 (0.67-1.4) kW
- Air Flow Volume 530/340/310 High / Med / Low
- Sound Power Level Indoor Unit 21.5/25/35.5/39.5 Quiet / Low / Medium / High / Turbo
- Sound Power Level Outdoor Unit 55 db(A)
- Sound Power Level Indoor Unit 54 db(A)
- Sound Power Level Outdoor Unit 64 db(A)
- Dehumidifying Volume 1.0 L/h
- Dehumidifying Volume 38.4 L/day
- Compressor Type ROTARY
- Liquid Line / Gas Line 1 / 4” - 3 / 8”
- Power Supply Wire Outdoor 3 x 1.5 / 10 Α
- Signal Wires 5 x 1.5 No x mm²
-
Dimensions
Indoor Unit 805x194x285 WxDxH -
Dimensions
Outdoor Unit 720x270x495 WxDxH - Net Weight Indoor / Outdoor 7.3/21.0 kg
- Refrigerant / Quantity R32/520 g
- Operation Temperature Range Outdoor Unit Cooling -15~50 °C
- Operation Temperature Range Outdoor Unit Heating -20~30 °C
- NBKU3VI-18WFI/ NBKU3VO-18
- Cooling Capacity 18.000 (6.200-21.000) Btu / h
- Cooling Capacity 5.28 (1.82-6.15) kWatt
- Heating Capacity 19.000 (4.400-23.000) Btu / h
- Heating Capacity 5.57 (1.29-6.74) kWatt
- Seasonal Efficiency In accordance to ΕΝ14.825
- Cooling
- Pdesign 5.2 kW
- Energy Class A++
- SEER 7.4
- Energy Consumption 247 kWh / year
- Heating Middle Zone
- Pdesign 4.1 kW
- Energy Class A+
- SCOP 4.0
- Energy Consumption 1.435 kWh / year
- Heating Warm Zone
- Pdesign 4.4 kW
- Energy Class A+++
- SCOP 5.1
- Energy Consumption 1.208 kWh / year
- Voltage / Frequency / Phase 220-240/50/1 V / Hz / Ph
- Current Input Cooling 6.70 (0.6-10.0) Α
- Current Input Heating 6.80 (0.9-10.2) Α
- Power Input Cooling 1.55 (0.14-2.3) kW
- Power Input Heating 1.57 (0.22-2.35) kW
- Air Flow Volume 840/680/540 High / Med / Low
- Sound Power Level Indoor Unit 20/26/36/42.5 Quiet / Low / Medium / High / Turbo
- Sound Power Level Outdoor Unit 56 db(A)
- Sound Power Level Indoor Unit 54 db(A)
- Sound Power Level Outdoor Unit 63 db(A)
- Dehumidifying Volume 1.6 L/h
- Dehumidifying Volume 48.0 L/day
- Compressor Type ROTARY
- Liquid Line / Gas Line 1 / 4” - 1 / 2”
- Power Supply Wire Outdoor 3 x 2.5 / 16 Α
- Signal Wires 5 x 1.5 No x mm²
-
Dimensions
Indoor Unit 957x213x302 WxDxH -
Dimensions
Outdoor Unit 805x330x554 WxDxH - Net Weight Indoor / Outdoor 10.0/32.7 kg
- Refrigerant / Quantity R32/1.080 g
- Operation Temperature Range Outdoor Unit Cooling -15~50 °C
- Operation Temperature Range Outdoor Unit Heating -20~30 °C
- NBKU3VI-24WFI/ NBKU3VO-24
- Cooling Capacity 24.000 (7.100-27.000) Btu / h
- Cooling Capacity 7.03 (2.08-7.91) kWatt
- Heating Capacity 25.000 (5.500-27.000) Btu / h
- Heating Capacity 7.33 (1.61-7.91) kWatt
- Seasonal Efficiency In accordance to ΕΝ14.825
- Cooling
- Pdesign 7.0 kW
- Energy Class A++
- SEER 6.1
- Energy Consumption 405 kWh / year
- Heating Middle Zone
- Pdesign 4.8 kW
- Energy Class A+
- SCOP 4.0
- Energy Consumption 1.680 kWh / year
- Heating Warm Zone
- Pdesign 5.6 kW
- Energy Class A+++
- SCOP 5.1
- Energy Consumption 1.537 kWh / year
- Voltage / Frequency / Phase 220-240/50/1 V / Hz / Ph
- Current Input Cooling 11.50 (1.8-13.8) Α
- Current Input Heating 11.00 (1.8-13.8) Α
- Power Input Cooling 2.6 (0.42-3.15) kW
- Power Input Heating 2.4 (0.3-2.75) kW
- Air Flow Volume 980/817/662 High / Med / Low
- Sound Power Level Indoor Unit 30/36/40.5/45 Quiet / Low / Medium / High / Turbo
- Sound Power Level Outdoor Unit 59 db(A)
- Sound Power Level Indoor Unit 59 db(A)
- Sound Power Level Outdoor Unit 67 db(A)
- Dehumidifying Volume 2.5 L/h
- Dehumidifying Volume 67.2 L/day
- Compressor Type ROTARY
- Liquid Line / Gas Line 3 / 8" - 5 / 8"
- Power Supply Wire Outdoor 3 x 2.5 / 16 Α
- Signal Wires 5 x 1.5 No x mm²
-
Dimensions
Indoor Unit 1.040x220x327 WxDxH -
Dimensions
Outdoor Unit 890x342x673 WxDxH - Net Weight Indoor / Outdoor 12.3/42.9 kg
- Refrigerant / Quantity R32/1.420 g
- Operation Temperature Range Outdoor Unit Cooling -15~50 °C
- Operation Temperature Range Outdoor Unit Heating -20~30 °C
More
Smart Defrosting
Energy saving and improved heating efficiency with intelligent defrosting. Intelligent defrosting is achieved only by sensors that control the need and duration of the defrosting process.
Temperature compensation capability
As the temperature sensed by the indoor unit's sensor can be different from the actual temperature in the room, the Temperature Compensation feature minimises this difference, creating an ideal environment.
Smart Preheat Function
Indoor fan speed is regulated automatically from the lowest grade to the setting grade according to the evaporator temperature when the unit starts heating operation
All DC Inverter
The fan motors of the indoor and outdoor units as well as the compressor have been upgraded to All DC Inverter technology. In this way, the compressor can change the capacity depending on the needs of the indoor atmosphere and create perfect conditions in your space.
Emergency Use
If the temperature sensor has any problem, a protection code will display on the air conditioner's screen. The air condition unit will stop operating until the problem will be fixed.
Refrigerant Leak Detection
The indoor unit will display an error code "EC" and it will automatically stop when diagnose refrigerant leakage to protect the compressor from overheating
Auto Error Diagnosis
Once abnormal operation or parts failure happens, the unit will shut off automatically to protect the system. Meanwhile it will indicate protection or error code for fast service.
Media Library for Nobu (NBKU3V)
User Manual - Energy Labels - High Resolution Photos
NOBU News
Make now your registration to NOBU newsletter, to learn everything about your favorite products